Statistical Analysis of Interfacial Gap in a Cementless Stem FE Model

Author:

Park Youngbae1,Choi DonOk1,Hwang Deuk Soo2,Yoon Yong-San1

Affiliation:

1. Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, KAIST 3022, Science Town, Daejeon 305-701, South Korea

2. Department of Orthopedic, Medical School, Chungnam National University, Daesadong 640, Jung-Ku, Daejeon 301-721, Korea

Abstract

In cementless total hip arthroplasty, a fair amount of interfacial gap exists between the femoral stem and the bone. However, the effect of these gaps on the mechanical stability of the stem is poorly understood. In this paper, a finite element model with various interfacial gap definitions is used to quantify the effect of interfacial gaps on the primary stability of a Versys Fiber Metal Taper stem under stair climbing loads. In the first part, 500 random interfacial gap definitions were simulated. The resulting micromotion was approximately inversely proportional to the contact ratio, and the variance of the micromotion was greater with a lower contact ratio. Moreover, when the magnitude of the micromotion was compared between the gap definitions that had contact at a specific site and those that had no contact at that site, it was found that gaps located in the proximal-medial region of the stem surface had the most important effect on the micromotion. In a second trial, 17 gap definitions mimicking a gap pattern that has been observed experimentally were simulated. For a given contact ratio, the micromotion observed in the second trial was lower than the average result of those in the first, where the gaps were placed randomly. In either trial, when the contact ratio was higher than 40%, the micromotion showed no significant difference (first trial) or a gentle slope (−0.24μm∕% in the second trial) in relation to the contact ratio. Considering the reported contact ratios for properly implanted stems, variations in the amount of interfacial gap would not likely cause a drastic difference in micromotion, and this effect could be easily overshadowed by other clinical factors. In conclusion, differences in interfacial gaps are not expected to have a noticeable effect on the clinical micromotion of this cementless stem.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference33 articles.

1. The Cementless Femoral Stem Revisited;Macari;J. South Orthop. Assoc.

2. The Dimensional Accuracy of Preparation of Femoral Cavity in Cementless Total Hip Arthroplasty;Wu;J. Zhejiang Univ., Sci.

3. A Quantitative Analysis of Bone Support Comparing Cementless Tapered and Distal Fixation Total Hip Replacements;Howard;J. Arthroplasty

4. What We Have Learned About Long-Term Cementless Fixation From Autopsy Retrievals;Sychterz;Clin. Orthop. Relat. Res.

5. Periprosthetic Bone Loss in Total Hip Arthroplasty: Polyethylene Wear Debris and the Concept of the Effective Joint Space;Schmalzried;J. Bone Joint Surg. Br.

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献