Radiation and Convection Heat Flux Sensor for High Temperature Gas Environment

Author:

Martins Nelson1,Carvalho Maria da Graça1,Afgan Naim1,Leontiev Alexander Ivanovich2

Affiliation:

1. Instituto Superior Técnico, Lisbon, Portugal

2. Moscow Technical University, Moscow, Russia

Abstract

The heat flux measurement is one of the essential parameter for the diagnostic of thermal systems. In the high temperature environment there are difficulties in differentiating between the convective and radiation component of heat flux on the heat transfer surface. A new method for heat flux measurement is being developed using a porous sensing element. The gas stream flowing through the porous element is used to measure the heat received by the sensor surface exposed to the hot gas environment and to control whether or not the sensing element receives the convection component of the total heat flux. It is possible to define a critical mass flow rate corresponding to the destruction of the boundary layer over the sensing element. With subcritical mass flow rate the porous sensing element will receive both the convective and radiative heat fluxes. A supercritical mass flow rate will eliminate the convective component of the total heat flux. Two consecutive measurements considering respectively a critical and a sub-critical mass flow rate can be used to determine separately the convection and radiation heat fluxes. A numerical model of sensor with appropriate boundary condition has been developed in order to perform analysis of possible options in the design of the sensor. The analysis includes: geometry of element, physical parameters of gas and solid and gas flow rate through the porous element. For the optimal selection of the relevant parameters an experimental set-up was designed, including the sensor element with corresponding cooling and monitoring system and high temperature radiation source. Applying the respective measuring procedure the calibration curve of the sensor was obtained. The linear dependency of the heat flux and respective temperature difference of the gas was verified. The accuracy analysis of the sensor reading has proved high linearity of the calibration curve and accuracy of ± 5%.

Publisher

American Society of Mechanical Engineers

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3