Enhancing the Accuracy of Vertical Ground Reaction Force Measurement During Walking Using Pressure-Measuring Insoles

Author:

DeBerardinis Jessica1,Trabia Mohamed B.2,Dufek Janet S.3,Le Gall Yann4,Da Silva Sacoto Nicolas5

Affiliation:

1. Department of Mechanical Engineering, University of Nevada, Box 454027, 4505 S. Maryland Pkwy, Las Vegas, NV 89154

2. Department of Mechanical Engineering, University of Nevada, Box 4005, 4505 S. Maryland Pkwy, Las Vegas, NV 89154

3. School of Integrated Health Sciences, University of Nevada, Box 3034, 4505 S. Maryland Pkwy, Las Vegas, NV 89154

4. École Supérieure d'Électronique de l'Ouest, 10 Boulevard Jean Jeanneteau, Angers 49100, France

5. École Supérieure d'Électronique de l'Ouest, 10 Boulevard Jean Jeanneteau, Angers 49100, France; Commission des Titres d'Ingenieur (CTI), 44 Rue Cambronne, Paris 75015, France

Abstract

Abstract Pressure-measuring insoles can be an attractive tool for measuring ground reaction force (GRF) since they are portable and can record multiple consecutive steps. Several researchers have, however, observed that these insoles are less accurate than instrumented force platforms. To address this issue, the authors identified transfer functions that best described each insole size to enhance the measurements of the vertical component of GRF during walking. GRF data were collected from 29 participants (6/23 male/female, 24.3 ± 6.7 yrs, 70.4 ± 23.9 kg, 1.66 ± 0.11 m) using Medilogic® pressure-measuring insoles and Kistler® force platforms for three walking trials. Participants provided the institutionally approved written consent (IRB #724468). The data from both instruments were preprocessed. A subset of the data was used to train the system identification toolbox (matlab) to identify the coefficients of several candidate transfer functions for each insole size. The resulting transfer functions were compared using all available data for each insole to assess which one modified the insole data to be closer to that of the force platform. All tested transfer functions moved the vertical component of GRF closer to the corresponding force platform data. Each insole size had a specific transfer model that that yielded the best results. Using system identification techniques produced transfer functions that, when using insole data of the vertical component of GRF as input, produced output that is comparable to the corresponding measurement using an instrumented force platform.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference36 articles.

1. A Comparison of Vertical Force and Temporal Parameters Produced by an in-Shoe Pressure Measuring System and a Force Platform;Clin. Biomech.,2001

2. Comparison of Ground Reaction Forces Measured With a Force Plate, FScan and Multiple Individual Force Sensors,2002

3. Assessing the Validity of Pressure-Measuring Insoles in Quantifying Gait Variables;J. Rehabil. Assist. Technol. Eng.,2018

4. Observations on the F-Scan in-Shoe Pressure Measuring System;Clin. Biomech.,1996

5. Validation of F-Scan Pressure Sensor System: A Technical Note;J. Rehabil. Res. Dev.,1998