Joint Gap Kinematics in Posterior-Stabilized Total Knee Arthroplasty Measured by a New Tensor With the Navigation System

Author:

Matsumoto Tomoyuki1,Muratsu Hirotsugu1,Tsumura Nobuhiro2,Mizuno Kiyonori1,Kuroda Ryosuke1,Yoshiya Shinichi3,Kurosaka Masahiro1

Affiliation:

1. Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan

2. Department of Orthopaedic Surgery, Hyogo Rehabilitation Center, 1070, Akebono-cho, Nishi-ku, Kobe, 651-2181, Japan

3. Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1, Mukogawa-cho, Nishinomiya, 663-8131, Japan

Abstract

Background: The management of soft tissue balance during surgery is essential for the success of total knee arthroplasty (TKA) but remains difficult, leaving it much to the surgeon’s feel. Previous assessments for soft tissue balance have been performed under unphysiological joint conditions, with patellar eversion and without the prosthesis only at extension and 90 deg of flexion. We therefore developed a new tensor for TKA procedures, enabling soft tissue balance assessment throughout the range of motion while reproducing postoperative joint alignment with the patellofemoral (PF) joint reduced and the tibiofemoral joint aligned. Our purpose in the present study was to clarify joint gap kinematics using the tensor with the CT-free computer assisted navigation system. Method of Approach: Joint gap kinematics, defined as joint gap change during knee motion, was evaluated during 30 consecutive, primary posterior-stabilized (PS) TKA with the navigation system in 30 osteoarthritic patients. Measurements were performed using a newly developed tensor, which enabled the measurement of the joint gap throughout the range of motion, including the joint conditions relevant after TKA with PF joint reduced and trial femoral component in place. Joint gap was assessed by the tensor at full extension, 5 deg, 10 deg, 15 deg, 30 deg, 45 deg, 60 deg, 90 deg, and 135 deg of flexion with the patella both everted and reduced. The navigation system was used to obtain the accuracy of implantations and to measure an accurate flexion angle of the knee during the intraoperative joint gap measurement. Results: Results showed that the joint gap varied depending on the knee flexion angle. Joint gap showed an accelerated decrease during full knee extension. With the PF joint everted, the joint gap increased throughout knee flexion. In contrast, the joint gap with the PF joint reduced increased with knee flexion but decreased after 60 deg of flexion. Conclusions: We clarified the characteristics of joint gap kinematics in PS TKA under physiological and reproducible joint conditions. Our findings can provide useful information for prosthetic design and selection and allow evaluation of surgical technique throughout the range of knee motion that may lead to consistent clinical outcomes after TKA.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference25 articles.

1. Technical Consideration in Total Knee Arthroplasty;Dorr;Clin. Orthop. Relat. Res.

2. Total Knee Arthroplasty;Insall;Clin. Orthop. Relat. Res.

3. The Total Condylar Knee Prosthesis: The First 5Years;Insall;Clin. Orthop. Relat. Res.

4. Technique and First Clinical Results of Robot-Assisted Total Knee Replacement;Siebert;The Knee

5. Positioning of Total Knee Arthroplasty With and Without Navigation Support. A. Prospective, Randomized Study;Sparmann;J. Bone Joint Surg. Br.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3