Overall Effectiveness for a Film Cooled Turbine Blade Leading Edge With Varying Hole Pitch

Author:

Dyson Thomas E.1,Bogard David G.2,Piggush Justin D.,Kohli Atul3

Affiliation:

1. e-mail:

2. e-mail:  The University of Texas at Austin, Austin, TX 78712

3. Pratt & Whitney, East Hartford, CT 06108 e-mail:

Abstract

Overall effectiveness, φ, for a simulated turbine blade leading edge was experimentally measured using a model constructed with a relatively high conductivity material selected so that the Biot number of the model matched engine conditions. The model incorporated three rows of cylindrical holes with the center row positioned on the stagnation line. Internally the model used an impingement cooling configuration. Overall effectiveness was measured for pitch variation from 7.6d to 11.6d for blowing ratios ranging from 0.5 to 3.0, and angle of attack from −7.7 deg to + 7.7 deg. Performance was evaluated for operation with a constant overall mass flow rate of coolant. Consequently when increasing the pitch, the blowing ratio was increased proportionally. The increased blowing ratio resulted in increased impingement cooling internally and increased convective cooling through the holes. The increased internal and convective cooling compensated, to a degree, for the decreased coolant coverage with increased pitch. Performance was evaluated in terms of laterally averaged φ, but also in terms of the minimum φ. The minimum φ evaluation revealed localized hot spots which are arguably more critical to turbine blade durability than the laterally averaged results. For small increases in pitch (from p/d = 7.6 to 9.6) there was only a small decrease in performance, but at p/d = 11.6 a significant reduction was observed.

Publisher

ASME International

Subject

Mechanical Engineering

Reference11 articles.

1. Gas Turbine Film Cooling;J. Propul. Power,2006

2. Film Cooling with Compound Angle Holes: Heat Transfer;ASME J. Turbomach.,1996

3. Adiabatic and Overall Effectiveness for a Film Cooled Blade,2004

4. Use of the Adiabatic Wall Temperature in Film Cooling to Predict Wall Heat Flux and Temperature,2008

5. Net Heat Flux Reduction and Overall Effectiveness for a Turbine Blade Leading Edge,2005

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献