Economic Potential of Innovative Receiver Concepts With Different Solar Field Configurations for Supercritical Steam Cycles
Author:
Singer Csaba1, Buck Reiner1, Pitz-Paal Robert1, Müller-Steinhagen Hans2
Affiliation:
1. Institute of Solar Research, German Aerospace Centre (DLR), Pfaffenwaldring 38-40, Stuttgart 70569, Germany e-mail: 2. TU Dresden, Helmholtzstraße 10, Dresden 01069, Germany e-mail:
Abstract
The cost reduction potential of solar power towers (SPT) is an important issue concerning its market introduction. Raising the steam process temperature and pressure can lead to a cost reduction due to increased overall plant efficiency. Thus, for new receiver configurations, a supercritical steam cycle operated at 300 bar/600 °C/610 °C live steam conditions was assumed. The considered systems include innovative direct absorption receivers, either with conventional or beam down heliostat field layouts. For the beam down option, the receiver is assumed to be a cylindrical vessel with a flow-through porous absorber structure at the internal lateral area of the cylinder. The direct absorption receiver option consists of a cylindrical barrel with downwards oriented aperture, whose absorber structure at the internal lateral area is cooled by a molten salt film. For the assessment, CFD based methods are developed and able to examine the receiver efficiency characteristics. Based on the receiver thermal efficiency characteristics and the solar field characteristics, the annual performance is evaluated using hourly time series. The assessment methodology is based on the European Concentrated Solar Thermal Roadmap (ECOSTAR) study and enables the prediction of the annual performance and the levelized cost of electricity (LCOE). Applying appropriate cost assumptions from literature, the LCOE are estimated for each considered SPT concept and compared to tubular receiver concepts with molten salt and liquid metal cooling. The power level of the compared concepts and the reference case is 200 MWel. The sensitivity of the specific cost assumptions is analyzed. No detailed evaluation is done for the thermal storage, but comparable storage utilization and costs are assumed for all cases. At optimized plant parameters, the results indicate a LCOE reduction potential of up to 0.5% for beam down and of up to 7.2% for the direct absorption receiver compared to today's state of the art molten salt solar tower technology.
Publisher
ASME International
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Reference39 articles.
1. High Flux Central Receivers of Molten Salts for the New Generation of Commercial Stand-Alone Solar Power Plants 2. Pacheco, J. E., Bradshaw, R. W., Dawson, D. B., De la Rosa, W., Gilbert, R., Goods, S. H., Hale, M. J., Jacobs, P., Jones, S. A., Kolb, G. J., Prairie, M. R., Reilly, H.E., Showalter, S. K., and Vant-Hull, L. L., 2002, “Final Test and Evaluation Results From the Solar Two Project,” Sandia Technical Report No. SAND2002-0120.26, 3. Reilly, H. E., and Kolb, G. J., 2001, “An Evaluation of Molten-Salt Power Towers Including the Results of the Solar Two Project,” Sandia Technical Report No. SAND2001-3674. 4. Zavoico, A. B., 2001, “Solar Power Tower Design Basis Document,” Sandia Technical Report No. SAND2001-2100. 5. Denk, T., 1999, “Weiterentwicklung des optischen Designs von Sekundärkonzentratoren,” DLR Report, DLR, Koln, Germany.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|