Affiliation:
1. Office of Developmental Automation and Control Technology, Institute for Computer Sciences and Technology, National Bureau of Standards, Washington, D.C.
Abstract
The storage of manipulator control functions in the CM AC memory is accomplished by an iterative process which, if the control function is sufficiently smooth, will converge. There are several different techniques for loading the CM AC memory depending on the amount of data which has already been stored and the degree of accuracy which is desired. The CM AC system lends itself to a “natural” partitioning of the control problem into manageable subproblems. At each level the CM AC controller translates commands from the next higher level into sequences of instructions to the next lower level. Data storage, or training, is accomplished first at the lowest level and must be completed, or nearly so, at each level before it can be initiated at the next higher level.
Subject
Computer Science Applications,Mechanical Engineering,Instrumentation,Information Systems,Control and Systems Engineering
Cited by
379 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献