Evaluation of Hand Motion Capture Protocol Using Static Computed Tomography Images: Application to an Instrumented Glove

Author:

Buffi James H.1,Sancho Bru Joaquín Luis23,Crisco Joseph J.45,Murray Wendy M.6789

Affiliation:

1. Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208; Sensory Motor Performance Program (SMPP), Rehabilitation Institute of Chicago, 345 East Superior Street, Suite 1406, Chicago, IL 60611 e-mail:

2. Department of Mechanical Engineering and Construction, Universitat Jaume I, Castelló 12071, Spain

3. Department of Mechanical Engineering and Construction, Universitat Jaume I, Campus de Riu Sec, Avinguda Vicent Sos Baynat, s/n, Castelló 12071, Spain e-mail:

4. Mem ASME Department of Orthopaedics, Brown University and Rhode Island Hospital, Providence, RI 02903

5. Warren Alpert Medical School, Brown University, 1 Hoppin Street, Suite 404, Coro West, Providence, RI 02903 e-mail:

6. Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208

7. Sensory Motor Performance Program (SMPP), Rehabilitation Institute of Chicago, 345 East Superior Street, Suite 1408B, Chicago, IL 60611

8. Departments of PM&R and PTHMS, Northwestern University, Chicago, IL 60611

9. Edward Hines Jr. VA Hospital, Hines, IL 60141 e-mail:

Abstract

There has been a marked increase in the use of hand motion capture protocols in the past 20 yr. However, their absolute accuracies and precisions remain unclear. The purpose of this technical brief was to present a method for evaluating the accuracy and precision of the joint angles determined by a hand motion capture protocol using simultaneously collected static computed tomography (CT) images. The method consists of: (i) recording seven functional postures using both the motion capture protocol and a CT scanner; (ii) obtaining principal axes of the bones in each method; (iii) calculating the flexion angle at each joint for each method as the roll angle of the composite, sequential, roll-pitch-yaw rotations relating the orientation of the distal bone to the proximal bone; and (iv) comparing corresponding joint angle measurements. For demonstration, we applied the method to a Cyberglove protocol. Accuracy and precision of the instrumented-glove protocol were calculated as the mean and standard deviation, respectively, of the differences between the angles determined from the Cyberglove output and the CT images across the seven postures. Implementation in one subject highlighted substantial errors, especially for the distal joints of the fingers. This technical note both clearly demonstrates the need for future work and introduces a solid, technical approach with the potential to improve the current state of such assessments in our field.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference26 articles.

1. Progress in the Development of the Index of ADL;Gerontologist,1970

2. The Use of the Motion Analysis System for Evaluation of Loss of Movement in the Finger;J. Hand Surgery-British Eur.,2000

3. Design and Validation of Low-Cost Assistive Glove for Hand Assessment and Therapy During Activity of Daily Living-Focused Robotic Stroke Therapy;J. Rehabil. Res. Dev.,2009

4. Design and Evaluation of a Low-Cost Instrumented Glove for Hand Function Assessment;J. Neuroeng. Rehabil.,2012

5. Kinematic and Dynamic Synergies of Human Precision-Grip Movements;J. Neurophysiol.,2005

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3