Affiliation:
1. Solar Energy Laboratory, University of Wisconsin, Madison, WI 53706
Abstract
A performance prediction methodology is developed which is applicable to most commercially available integral collection-storage passive solar domestic hot water systems. A computer model of a general ICS component was created to be compatible with the transient simulation program TRNSYS[3], and was used to develop and verify the simpler monthly performance prediction method. The method uses the system parameters from available test methods, monthly average climatic data, and load size to predict long term performance of ICS systems.
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献