Affiliation:
1. Los Alamos National Laboratory, Los Alamos, N.M. 87545
Abstract
This paper discusses the design, construction, and initial operation of the solar pond at Los Alamos National Laboratory. This 232 m2 pond is the third facet of a threefold approach to the study of hydrodynamic effects in double diffusive systems, such as solar ponds. The first two facets are flow visualization experiments and one-dimensional laboratory tank tests [1]. Data from these experiments, in addition to other data from the literature, are used to validate the one-dimensional dynamic performance pond model developed by one of the authors [2]. Our particular interest is the boundary-layer structure at the interfaces between the convecting and nonconvecting zones, interaction between the zones, and surface zone effects including diurnal heating effects and wind-induced turbulence. A pond, such as the one this paper describes, provides possible insight into several pond physical processes that may not occur in smaller-scale laboratory experiments due to edge effects, or may be impossible to simulate.
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献