Measurement of Pressure Loss Throughout a Clogged Steam Generator Tube Support Plate in Single Phase Flow

Author:

Brunin Olivier1,Deotto Geoffrey1,David Franck2,Pillet Joe¨l2,Dague Gilles3,Nicoli Alexandre3

Affiliation:

1. EDF SEPTEN, Villeurbanne, France

2. EDF MFEE, Chatou, France

3. AREVA NP SAS, Paris La De´fense, France

Abstract

After a period of several years of operation, steam generators can be affected by fouling and clogging. Fouling means that deposits of sludge accumulate on tubes or tube support plates (TSP). That results in a reduction of heat exchange capabilities and can be modelled by means of a fouling factor. Clogging is a reduction of flow free area due to an accumulation of sludge in the space between TSP and tubes. The increase of the clogging ratio results in an increase of the overall TSP pressure loss coefficient. The link between the clogging ratio and the overall TSP pressure loss coefficient is the most important aspect of our capability to accurately calculate the thermal-hydraulics of clogged steam generators. The aim of the paper is to detail the experimental approach chosen by EDF and AREVA NP to address the calculation uncertainties. The calculation method is classically based on the computation of a single-phase (liquid-only) pressure loss coefficient, which is multiplied by a two-phase flow factor. Both parameters are well documented and can be derived on the basis of state of the art methods such as IDEL’CIK diagrams and CHISHOLM formula. The experimental approach consists of a validation of the correlations by performing tests on a mock-up section with an upward flow throughout a vertical array of tubes. A mixture of water and vapour refrigerant R116 is used to represent two-phase flows. The tube bundle is composed of a 25 tubes array in a square arrangement. The overall height of the mock-up is 2 m. Eight test TSPs were manufactured, considering eight different clogging configurations: six plates with a typical clogging profile at six clogging ratios (0, 44%, 58%, 72%, 86%, 95%), and two plates with a clogging ratio of 72% associated with two different clogging profiles (large bending radius profile and rectangular profile). A series of tests were performed in 2009 in single-phase flow conditions. Two-phase flow tests with a mixture of liquid water and vapour refrigerant R116 will be performed in 2010. The paper illustrates the main results obtained during the single-phase tests performed in 2009.

Publisher

ASMEDC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3