Mechanical and Electrical Responses of the Squid Giant Axon to Simple Elongation

Author:

Galbraith J. A.1,Thibault L. E.1,Matteson D. R.2

Affiliation:

1. Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104; Marine Biological Laboratory, Woods Hole, MA 02543

2. Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA 19104; Marine Biological Laboratory, Woods Hole, MA 02543

Abstract

There is a limited amount of information available on the mechanical and functional response of the nervous system to loading. While deformation of cerebral, spinal, or peripheral nerve tissue can have particularly severe consequences, most research in this area has concentrated on either demonstrating in-vivo functional changes and disclosing the effected anatomical pathways, or describing material deformations of the composite structure. Although such studies have successfully produced repeatable traumas, they have not addressed the mechanisms of these mechanically induced injuries. Therefore, a single cell model is required in order to gain further understanding of this complex phenomena. An isolated squid giant axon was subjected to controlled uniaxial loading and its mechanical and physiological responses were monitored with an instrument specifically designed for these experiments. These results determined that the mechanical properties of the isolated axon are similar to those of other soft tissues, and include features such as a nonlinear load-deflection curve and a hysteresis loop upon unloading. The mechanical response was modeled with the quasi-linear viscoelastic theory (Fung, 1972). The physiological response of the axon to quasi-static loading was a small reversible hyperpolarization; however, as the rate of loading was increased, the axon depolarized and the magnitude and the time needed to recover to the original resting potential increased in a nonlinear fashion. At elongations greater than twenty percent an irreversible injury occurs and the membrane potential does not completely recover to baseline.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3