Evaluation by Liquid Crystal Thermography of Transient Surface Temperature Distribution in Radiant Floor Cooling Applications and Assessment of Analytical and Numerical Models

Author:

Bizzarri Marco1ORCID,Conti Paolo1,Glicksman Leon R.2,Schito Eva13,Testi Daniele1ORCID

Affiliation:

1. Department of Energy, Systems, Territory and Constructions Engineering (DESTEC), University of Pisa , Pisa 56122, Italy

2. Department of Architecture, Massachusetts Institute of Technology , Cambridge, MA 02139

3. University of Pisa

Abstract

Abstract The purpose of our study is to evaluate the surface temperature distribution on a radiant floor, particularly focusing on space cooling operations, to assess the presence of nonuniformities. In fact, knowing the temperature difference between the average superficial temperature and the coldest spot can be a useful indication for condensation prevention. Primarily, we performed an experimental campaign in test rooms using temperature sensors and liquid crystal thermography. This allowed us to evaluate the floor temperature distribution both on a local scale, influenced by the discontinuous presence of buried water pipes, and on a macroscale, influenced by internal use, objects, and boundary conditions of the surrounding space. Then, the experimental temperature field on the radiant floor surface has been compared with analytical and numerical models in steady-state and transient phases, respectively. The results indicate limited superficial temperature variations that become more significant at larger tube spacings and under transient conditions. In particular, the numerical transient analysis showed that shortly after a step change in the pipe's temperature boundary condition, a larger variation is locally observable on the floor, which then decays to the new steady-state conditions, presenting more uniformity. However, local effects are generally overshadowed by macro-effects, especially for practical scenarios where many objects, furnishings, and different boundary conditions are present. Finally, as a conservative guideline for the cooling system control, we recommend maintaining the average superficial floor temperature at least 1 °C above the dew point, to account for the described nonuniformities.

Publisher

ASME International

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3