Adaptive Surrogate Modeling for Efficient Coupling of Musculoskeletal Control and Tissue Deformation Models

Author:

Halloran Jason P.1,Erdemir Ahmet1,van den Bogert Antonie J.1

Affiliation:

1. Department of Biomedical Engineering (ND-20), Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195

Abstract

Finite element (FE) modeling and multibody dynamics have traditionally been applied separately to the domains of tissue mechanics and musculoskeletal movements, respectively. Simultaneous simulation of both domains is needed when interactions between tissue and movement are of interest, but this has remained largely impractical due to the high computational cost. Here we present a method for the concurrent simulation of tissue and movement, in which state of the art methods are used in each domain, and communication occurs via a surrogate modeling system based on locally weighted regression. The surrogate model only performs FE simulations when regression from previous results is not within a user-specified tolerance. For proof of concept and to illustrate feasibility, the methods were demonstrated on an optimization of jumping movement using a planar musculoskeletal model coupled to a FE model of the foot. To test the relative accuracy of the surrogate model outputs against those of the FE model, a single forward dynamics simulation was performed with FE calls at every integration step and compared with a corresponding simulation with the surrogate model included. Neural excitations obtained from the jump height optimization were used for this purpose and root mean square (RMS) difference between surrogate and FE model outputs (ankle force and moment, peak contact pressure and peak von Mises stress) were calculated. Optimization of the jump height required 1800 iterations of the movement simulation, each requiring thousands of time steps. The surrogate modeling system only used the FE model in 5% of time steps, i.e., a 95% reduction in computation time. Errors introduced by the surrogate model were less than 1mm in jump height and RMS errors of less than 2N in ground reaction force, 0.25Nm in ankle moment, and 10kPa in peak tissue stress. Adaptive surrogate modeling based on local regression allows efficient concurrent simulations of tissue mechanics and musculoskeletal movement.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference34 articles.

1. A Survey of Finite Element Analysis in Orthopedic Biomechanics: The First Decade;Huiskes;J. Biomech.

2. Finite Element Methods in Spine Biomechanics Research;Gilbertson;Crit. Rev. Biomed. Eng.

3. Computer Modeling and Simulation of Human Movement;Pandy;Annu. Rev. Biomed. Eng.

4. Physical Validation of a Patient-Specific Contact Finite Element Model of the Ankle;Anderson;J. Biomech.

5. Physiologically Based Boundary Conditions in Finite Element Modelling;Speirs;J. Biomech.

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献