Development and Assessment of a Microcomputed Tomography Compatible Five Degrees-of-Freedom Knee Joint Motion Simulator

Author:

Blokker Alexandra M.1,Getgood Alan M.2,Curiale Nathan J.3,Nikolov Hristo N.4,Laing Justin G.5,Holdsworth David W.6,Burkhart Timothy A.7

Affiliation:

1. Department of Biomedical Engineering, Robarts Research Institute, Western University, London, ON N6A 5B9, Canada

2. Department of Surgery, Fowler Kennedy Sports Medicine Clinic, Western University, London, ON N6A 3K7, Canada

3. Department of Mechanical Engineering, Western University, London, ON N6A 5B9, Canada

4. Robarts Research Institute, Western University, London, ON N6A 5B7, Canada

5. Department of Biomedical Engineering, Western University, London, ON N6A 5B9, Canada

6. Professor Department of Medical Biophysics, Western University, London, ON N6A 5C1, Canada

7. Department Mechanical Engineering, Lawson Health Research Institute, Western University, 1151 Richmond Road, London, ON N6A 5B9, Canada

Abstract

Currently available knee joint kinematic tracking systems fail to nondestructively capture the subtle variation in joint and soft tissue kinematics that occur in native, injured, and reconstructed joint states. Microcomputed tomography (CT) imaging has the potential as a noninvasive, high-resolution kinematic tracking system, but no dynamic simulators exist to take advantage of this. The purpose of this work was to develop and assess a novel micro-CT compatible knee joint simulator to quantify the knee joint's kinematic and kinetic response to clinically (e.g., pivot shift test) and functionally (e.g., gait) relevant loading. The simulator applies closed-loop, load control over four degrees-of-freedom (DOF) (internal/external rotation, varus/valgus rotation, anterior/posterior translation, and compression/distraction), and static control over a fifth degree-of-freedom (flexion/extension). Simulator accuracy (e.g., load error) and repeatability (e.g., coefficient of variation) were assessed with a cylindrical rubber tubing structure and a human cadaveric knee joint by applying clinically and functionally relevant loads along all active axes. Micro-CT images acquired of the joint at a loaded state were then used to calculate joint kinematics. The simulator loaded both the rubber tubing and the cadaveric specimen to within 0.1% of the load target, with an intertrial coefficient of variation below 0.1% for all clinically relevant loading protocols. The resultant kinematics calculated from the acquired images agreed with previously published values, and produced errors of 1.66 mm, 0.90 mm, 4.41 deg, and 1.60 deg with respect to anterior translation, compression, internal rotation, and valgus rotation, respectively. All images were free of artifacts and showed knee joint displacements in response to clinically and functionally loading with isotropic CT image voxel spacing of 0.15 mm. The results of this study demonstrate that the joint-motion simulator is capable of applying accurate, clinically and functionally relevant loads to cadaveric knee joints, concurrent with micro-CT imaging. Nondestructive tracking of bony landmarks allows for the precise calculation of joint kinematics with less error than traditional optical tracking systems.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference32 articles.

1. National Electronic Injury Surveillance System 1998–2017 on NEISS Online Database, released April, 2018,2019

2. Return to Sport After ACL Reconstruction: How, When and Why? A Narrative Review of Current Evidence;Joints,2015

3. Are the Kinematics of the Knee Joint Altered During the Loading Response Phase of Gait in Individuals With Concurrent Knee Osteoarthritis and Complaints of Joint Instability? A Dynamic Stereo X-Ray Study;Clin. Biomech.,2012

4. Association of Knee Injuries With Accelerated Knee Osteoarthritis Progression: Data From the Osteoarthritis Initiative;Arthritis Care Res.,2014

5. Effect of ACL Transection on Internal Tibial Rotation in an In Vitro Simulated Pivot Landing;J. Bone Jt. Surg.,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3