Freezing by a Flat, Circular Surface Cryoprobe of a Tissue Phantom With an Embedded Cylindrical Heat Source Simulating a Blood Vessel
Author:
Massalha Loay1, Shitzer Avraham1
Affiliation:
1. Department of Mechanical Engineering, Technion, Israel Institute of Technology, Haifa, Israel 32000
Abstract
The effects of a thermally-significant blood vessel, simulated by an embedded acrylic tube, 4.8 mm outer diameter, on the freezing field caused by a surface cryoprobe were studied experimentally in a tissue phantom. The flat, 15 mm diameter, circular cryoprobe was operated at a constant cooling rate of −8°C/min by liquid nitrogen down to −160°C. Water flow rates of 30 and 100 ml/min, at a constant temperature of 32.5°C, were maintained in the embedded tube. The latter flow rate is typical to the lower range of blood flows in large arteries in the human body. The phase changing medium (PCM) used was a 30/70% by volume mashed potatoes flakes–water solution. Temperature measurements inside the PCM were performed in one plane perpendicular to the embedded tube, relative to which the cryoprobe was placed at 5 locations in separate experiments. This novel experimental method reduced the perturbation caused by the thermocouple junctions while facilitating rather detailed measurements of the temperature fields developing in the PCM. Results show the development of two hump-like formations on either side of the embedded tube. Freezing was retarded in the region away from the surface cryoprobe and under the tube. This accentuated the dominance of the axial effects, due to the embedded tube, over the radial ones due to the cryoprobe. Results of this study should be considered in designing protocols of cryosurgical procedures performed in the vicinity of thermally-significant blood vessels.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference23 articles.
1. Shepherd, J., and Dawber, R. P. R., 1981, “The Historical and Scientific Basis of Cryosurgery,” Clin. Exp. Dermatol., 7, pp. 321–328. 2. Gage, A. A.
, 1992, “Progress in Cryosurgery,” Cryobiology, 29, pp. 300–304. 3. Orpwood, R. D.
, 1981, “Biophysical and Engineering Aspects of Cryosurgery,” Phys. Med. Biol., 26, pp. 404–414. 4. Onik, G. M., 1995, “Prostate Cryoablation: A Reappraisal,” in Percutaneous Cryoablation, G. M. Onik, B. Rubinsky, G. Watson, and R. J. Ablin, eds., Quality Medical Publications, St. Louis, MO. 5. Walder, H. A. D., 1971, “Experimental Cryosurgery,” in Cryogenics in Surgery, H. Van Leden and W. G. Cahan, eds., Medical Examination Publishing Co.
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|