Exploring the Impact of Sensor Location on Seismocardiography-Derived Cardiac Time Intervals

Author:

Mann Aysha J.1,Gamage Peshala Thibbotuwawa2,Kakavand Bahram3,Taebi Amirtahà1

Affiliation:

1. Department of Agricultural and Biological Engineering, Mississippi State University , Mississippi State, MS 39762

2. Department of Biomedical Engineering and Sciences, Florida Institute of Technology , Melbourne, FL 32901

3. Department of Cardiology, Nemours Children's Hospital , Orlando, FL 32827

Abstract

Abstract Cardiac time intervals (CTIs) are important parameters for evaluating cardiac function and can be measured noninvasively through electrocardiography (ECG) and seismocardiography (SCG). SCG signals exhibit distinct spectrotemporal characteristics when acquired from various locations on the chest. Thus, this study aimed to explore how SCG measurement location affects the estimation of SCG-based CTIs. ECG and SCG signals were acquired from 14 healthy adults, with three accelerometers placed on the top, middle, and bottom of the sternum. A custom-built algorithm was developed to estimate heart rates (HRs) from ECG (HRECG) and SCG (HRSCG) signals. Moreover, SCG fiducial points and CTIs, including aortic valve opening and closure, R-R interval, pre-ejection period, left ventricular ejection time, and electromechanical systole, were estimated from the SCG signals at different sternal locations. The average and correlation coefficient (R2) of the CTIs and HRs derived from all three locations were compared, along with the analysis of mean differences for the CTIs and their corresponding sensor locations. The results indicated strong correlations between HRECG and HRSCG, with average R2 values of 0.9930, 0.9968, and 0.9790 for the top, middle, and bottom sternal locations, respectively. Additionally, the study demonstrated that SCG-based CTIs varied depending on the SCG measurement locations. In conclusion, these findings underscore the importance of establishing consistent protocols for reporting CTIs based on SCG. Furthermore, they call for further investigation to compare estimated CTIs with gold-standard methods like echocardiography to identify the best SCG measurement location for accurate CTI estimations.

Publisher

ASME International

Subject

General Earth and Planetary Sciences,General Environmental Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3