Joint Coordinate System Using Functional Axes Achieves Clinically Meaningful Kinematics of the Tibiofemoral Joint as Compared to the International Society of Biomechanics Recommendation

Author:

Pourtabib Joe1,Hull M. L.234

Affiliation:

1. Department of Biomedical Engineering, University of California Davis , Davis, CA 95616

2. Department of Biomedical Engineering, University of California Davis , Davis, CA 95616 ; , Davis, CA 95616 ; , Sacramento, CA 95817

3. Department of Mechanical Engineering, University of California Davis , Davis, CA 95616 ; , Davis, CA 95616 ; , Sacramento, CA 95817

4. Department of Orthopaedic Surgery, University of California Davis Medical Center , Davis, CA 95616 ; , Davis, CA 95616 ; , Sacramento, CA 95817

Abstract

Abstract Quantification of clinically meaningful tibiofemoral motions requires a joint coordinate system (JCS) with motions free from kinematic crosstalk errors. The objectives were to use a JCS with literature-backed functional axes (FUNC) and a JCS recommended by the International Society of Biomechanics (ISB) to determine tibiofemoral kinematics of the native (i.e., healthy) knee, determine variability associated with each JCS, and determine whether the FUNC JCS significantly reduced kinematic crosstalk errors compared to the ISB JCS. Based on a kinematic model consisting of a three-cylindric joint chain, the FUNC JCS included functional flexion–extension (F–E) and internal-external (I–E) tibial rotation axes. In contrast, the ISB JCS included F–E and I–E axes defined using anatomic landmarks. Single-plane fluoroscopic images in 13 subjects performing a weighted deep knee bend were analyzed. Tibiofemoral kinematics using the FUNC JCS fell within the physiological range of motion in all six degrees-of-freedom. Internal tibial rotation averaged 13 deg for the FUNC JCS versus 10 deg for the ISB JCS and motions in the other four degrees-of-freedom (collectively termed off-axis motions) were minimal as expected based on biomechanical constraints. Off-axis motions for the ISB JCS were significantly greater; maximum valgus rotation was 4 deg and maximum anterior and distraction translations were 9 mm and 25 mm, respectively, which is not physiologic. Variabilities in off-axis motions were significantly greater with the ISB JCS (p < 0.0002). The FUNC JCS achieved clinically meaningful kinematics by significantly reducing kinematic crosstalk errors and is the more suitable coordinate system for quantifying tibiofemoral motions.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3