Evaluation of Cement Stresses in Finite Element Analyses of Cemented Orthopaedic Implants
Author:
Lennon A. B.1, Prendergast P. J.1
Affiliation:
1. Department of Mechanical Engineering, Trinity College, Dublin 2, Ireland
Abstract
Stress analysis of the cement fixation of orthopaedic implants to bone is frequently carried out using finite element analysis. However, the stress distribution in the cement layer is usually intricate, and it is difficult to report it in a way that facilitates comparison of implants for pre-clinical testing. To study this problem, and make recommendations for stress reporting, a finite element analysis of a hip prosthesis implanted into a synthetic composite femur is developed. Three cases are analyzed: a fully bonded implant, a debonded implant, and a debonded implant where the cement is removed distal to the stem tip. In addition to peak stresses, and contour and vector plots, a stressed volume and probability-of-failure analysis is reported. It is predicted that the peak stress is highest for the debonded stem, and that removal of the distal cement more than halves this peak stress. This would suggest that omission of the distal cement is good for polished prostheses (as practiced for the Exeter design). However, if the percentage of cement stressed above a certain threshold (say 3 MPa) is considered, then the removal of distal cement is shown to be disadvantageous because a higher volume of cement is stressed to above the threshold. Vector plots clearly demonstrate the different load transfer for bonded and debonded prostheses: A bonded stem generates maximum tensile stresses in the longitudinal direction, whereas a debonded stem generates most tensile stresses in the hoop direction, except near the tip where tensile longitudinal stresses occur due to subsidence of the stem. Removal of the cement distal to the tip allows greater subsidence but alleviates these large stresses at the tip, albeit at the expense of increased hoop stresses throughout the mantle. It is concluded that a thorough analysis of cemented implants should not report peak stress, which can be misleading, but rather stressed volume, and that vector plots should be reported if a precise analysis of the load transfer mechanism is required.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference25 articles.
1. Britton, A. R., Murray, D. W., Bulstrode, C. J., McPhearson, K., and Denham, R. A., 1997, “Pain Levels After Total Hip Replacement. Their Use as Endpoints for Survival Analysis,” J. Bone Jt. Surg., 79B, pp. 93–98. 2. Malchau, H., and Herberts, P., 1998, “Prognosis of Total Hip Replacement. Revision and Re-revision Rate in THR. A Revision Risk Study of 148,359 Primary Operations,” scientific exhibition presented at the 65th Annual Meeting of the American Academy of Orthopaedic Surgeons, New Orleans, LA. 3. Huiskes, R., and Boeklagen, R., 1989, “Mathematical Shape Optimization of Hip Prosthesis Design,” J. Biomech., 22, pp. 793–804. 4. Lee, A. J. C., 1994, “Implants for Fixation With and Without a Collar,” in: Technical Principles, Design, and Safety of Joint Implants, G. H. Buchhorn and H.-G. Willert, eds., Hogrefe & Hubber, Bern, pp. 128–132. 5. Harris, W. H.
, 1992, “Is It Advantageous to Strengthen the Cement Metal Interface and Use a Collar for Cemented Femoral Components of Total Hip Replacements,” Clin. Orthop. Relat. Res., 285, pp. 67–72.
Cited by
56 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|