Sensitivity of Digital Thermal Monitoring Parameters to Reactive Hyperemia

Author:

Akhtar Mohammad W.1,Kleis Stanley J.1,Metcalfe Ralph W.1,Naghavi Morteza2

Affiliation:

1. Department of Mechanical Engineering, University of Houston, Houston, TX 77204

2. Fairway Medical Technologies, Inc., 710 N. Post Oak Road, Suite 204, Houston, TX 77024

Abstract

Both structural and functional evaluations of the endothelium exist in order to diagnose cardiovascular disease (CVD) in its asymptomatic stages. Vascular reactivity, a functional evaluation of the endothelium in response to factors such as occlusion, cold, and stress, in addition to plasma markers, is the most widely accepted test and has been found to be a better predictor of the health of the endothelium than structural assessment tools such as coronary calcium scores or carotid intima-media thickness. Among the vascular reactivity assessment techniques available, digital thermal monitoring (DTM) is a noninvasive technique that measures the recovery of fingertip temperature after 2–5 min of brachial occlusion. On release of occlusion, the finger temperature responds to the amount of blood flow rate overshoot referred to as reactive hyperemia (RH), which has been shown to correlate with vascular health. Recent clinical trials have confirmed the potential importance of DTM as an early stage predictor of CVD. Numerical simulations of a finger were carried out to establish the relationship between DTM and RH. The model finger consisted of essential components including bone, tissue, major blood vessels (macrovasculature), skin, and microvasculature. The macrovasculature was represented by a pair of arteries and veins, while the microvasculature was represented by a porous medium. The time-dependent Navier–Stokes and energy equations were numerically solved to describe the temperature distribution in and around the finger. The blood flow waveform postocclusion, an input to the numerical model, was modeled as an instantaneous overshoot in flow rate (RH) followed by an exponential decay back to baseline flow rate. Simulation results were similar to clinically measured fingertip temperature profiles in terms of basic shape, temperature variations, and time delays at time scales associated with both heat conduction and blood perfusion. The DTM parameters currently in clinical use were evaluated and their sensitivity to RH was established. Among the parameters presented, temperature rebound (TR) was shown to have the best correlation with the level of RH with good sensitivity for the range of flow rates studied. It was shown that both TR and the equilibrium start temperature (representing the baseline flow rate) are necessary to identify the amount of RH and, thus, to establish criteria for predicting the state of specific patient’s cardiovascular health.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference51 articles.

1. World Health Organization, 2007, “Health Topics, Cardiovascular Diseases,” Fact Sheet No. 317.

2. Some Lessons in Cardiovascular Epidemiology From Framingham;Kannel;Am. J. Cardiol.

3. High Prevalence of Coronary Atherosclerosis in Asymptomatic Teenagers and Young Adults Evidence From Intravascular Ultrasound;Tuzcu;Circulation

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3