Abstract
The results of the steady-state analysis presented in Part 1 are applied to a quasi-steady analysis isothermal flow in constant diameter tubes (with straight-through unions at the extremities) connected to a closed sensing volume. The ranges of transient pressure inputs and geometric variables were chosen to simulate typical missile pressure sensing systems. The effect of high inlet temperature during descent was not studied, all tests being at room temperature. The correlation of theory with experiment for three types of input (impulse, continuous, and shock) is shown to be quantitative over the range of variables studied. It is concluded that the empirical analysis presented herein provides an adequate working theory for pressure lag during transient flight.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Pulsation Control in Pressure Metering Systems;Journal of Low Frequency Noise, Vibration and Active Control;1994-03