Static Indentation of Anisotropic Biomaterials Using Axially Asymmetric Indenters—a Computational Study
Affiliation:
1. Department of Mechanical Engineering, University of South Carolina, 300 South Main, Columbia, SC 29208 Telephone: 803.777.0084 Fax: 803.777.0106
Abstract
Indentation has historically been used by biomechanicians to extract the small strain elastic or viscoelastic properties of biological tissues. Because of the axisymmetry of indenters used in these studies however, analysis of the results requires the assumption of material isotropy and often yields an “effective” elastic modulus. Since most biological tissues such as bone and myocardium are known to be anisotropic, the use of conventional indentation techniques for estimating material properties is therefore limited. The feasibility of using an axially asymmetric indenter to determine material directions and in-plane material properties for anisotropic tissue is explored here using finite element analysis. The load versus displacement curves as would be measured by an indenter depend on the orientation of the indenter cross section relative to the in-plane material axes, thus suggesting a method for determining the underlying material directions. Additionally, the stiffness of the tissue response to indentation is sensitive to the values of the in-plane anisotropic material properties and prestretches, and thus test results can be used to back out relevant constitutive parameters.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference25 articles.
1. Lanir, Y., and Fung, Y. C., 1974, “Two-Dimensional Mechanical Properties of Rabbit Skin. II. Experimental Results,” J. Biomech., 7, pp. 171–182. 2. Billiar, K. L., and Sacks, M. S., 2000, “Biaxial Mechanical Properties of the Natural and Glutaraldehyde Treated Aortic Valve Cusp. Part I. Experimental Results,” J. Biomech. Eng., 122, pp. 23–30. 3. Demer, L. L., and Yin, F. C. P., 1983, “Passive Biaxial Mechanical Properties of Isolated Canine Myocardium,” Journal of Physiology, 339, pp. 615–630. 4. Dokos, S., LeGrice, I. J., Smaill, B. H., Kar, J., and Young, A. A., 2000, “A Triaxial Measurement Shear-Test Device for Soft Biological Tissues,” J. Biomech. Eng., 122, pp. 471–478. 5. Okamoto, R. J., Moulton, M. J., Peterson, S. J., Li, D., Pasque, M. K., and Guccione, J. M., 2000, “Epicardial Suction: A New Approach to Mechanical Testing of the Passive Ventricular Wall,” J. Biomech. Eng., 122, pp. 479–487.
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|