Global Sensitivity Analysis for Patient-Specific Aortic Simulations: The Role of Geometry, Boundary Condition and Large Eddy Simulation Modeling Parameters

Author:

Xu Huijuan1,Baroli Davide2,Veneziani Alessandro3

Affiliation:

1. School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332; Siemens Coporate Technology, Princeton, NJ 08540

2. Aachen Institute for Advanced Study in Computational Engineering Science, Aachen 52062, Germany

3. Department of Mathematics, Emory University, Atlanta, GA 30322; Department of Computer Science, Emory University, Atlanta, GA 30322

Abstract

Abstract Numerical simulations for computational hemodynamics in clinical settings require a combination of many ingredients, mathematical models, solvers and patient-specific data. The sensitivity of the solutions to these factors may be critical, particularly when we have a partial or noisy knowledge of data. Uncertainty quantification is crucial to assess the reliability of the results. We present here an extensive sensitivity analysis in aortic flow simulations, to quantify the dependence of clinically relevant quantities to the patient-specific geometry and the inflow boundary conditions. Geometry and inflow conditions are generally believed to have a major impact on numerical simulations. We resort to a global sensitivity analysis, (i.e., not restricted to a linearization around a working point), based on polynomial chaos expansion (PCE) and the associated Sobol' indices. We regard the geometry and the inflow conditions as the realization of a parametric stochastic process. To construct a physically consistent stochastic process for the geometry, we use a set of longitudinal-in-time images of a patient with an abdominal aortic aneurysm (AAA) to parametrize geometrical variations. Aortic flow is highly disturbed during systole. This leads to high computational costs, even amplified in a sensitivity analysis -when many simulations are needed. To mitigate this, we consider here a large Eddy simulation (LES) model. Our model depends in particular on a user-defined parameter called filter radius. We borrowed the tools of the global sensitivity analysis to assess the sensitivity of the solution to this parameter too. The targeted quantities of interest (QoI) include: the total kinetic energy (TKE), the time-average wall shear stress (TAWSS), and the oscillatory shear index (OSI). The results show that these indexes are mostly sensitive to the geometry. Also, we find that the sensitivity may be different during different instants of the heartbeat and in different regions of the domain of interest. This analysis helps to assess the reliability of in silico tools for clinical applications.

Funder

National Science Foundation

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference55 articles.

1. Patient-Specific Cfd Modelling in the Thoracic Aorta With Pc-Mri–Based Boundary Conditions: A Least-Square Three-Element Windkessel Approach;Int. J. Numer. Methods Biomed. Eng.,2018

2. Coupled Morphological–Hemodynamic Computational Analysis of Type b Aortic Dissection: A Longitudinal Study;Ann. Biomed. Eng.,2018

3. Helical Flow in Carotid Bifurcation as Surrogate Marker of Exposure to Disturbed Shear;J. Biomech.,2012

4. High Levels of 18f-Fdg Uptake in Aortic Aneurysm Wall Are Associated With High Wall Stress;Eur. J. Vasc. Endovascular Surg.,2010

5. Patient-Specific Analysis of Post-Operative Aortic Hemodynamics: A Focus on Thoracic Endovascular Repair (Tevar);Comput. Mech.,2014

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3