Implant placement plays a key role in trauma and orthopedics. In this paper, a generic technological concept for implant positioning assistance is outlined. The system utilizes conventional radiographic devices for imaging and tracking and embeds into surgical workflows without the need for complex navigation equipment. It is based on feature extraction from cylindrical hole-projections in X-ray images for determining spatial alignment of implant and anatomy. Basic performance of a prototype system was experimentally verified in terms of tracking accuracy and robustness under varying conditions. In a second step, the system was developed into a set of application modules, each serving a pressing clinical need: Plating of the proximal humerus, cephalic nail and dynamic hip-screw placement, general anatomic plating, distal nail interlocking with adjustment of femoral anteversion and corrective osteotomies. Module prototypes were tested according to their degree of maturity from feasibility assessment in wet-labs to clinical handling tests. Orientation tracking of reference objects yielded an accuracy and precision of 0.1±0.71 deg (mean±standard deviation) with a maximum error of 4.68 deg at unfavorable conditions. This base-performance translated, e.g., into a precision of ±1.2 mm (standard deviation) screw-tip to joint distance at proximal humerus plating, or into a precision of lag screw positioning in the femoral head of ±0.6 mm in craniocaudal and ±1.6 mm in anterioposterior direction. The concept revealed strong potential to improve surgical outcomes in a broad range of orthopedic applications due to its generic and simplistic nature. Comprehensive validation activities must follow for clinical introduction.
Subject
Biomedical Engineering,Medicine (miscellaneous)
Reference30 articles.
1. AO Principles of Fracture Management;Thieme,2017
2. Awareness of Tip-Apex Distance Reduces Failure of Fixation of Trochanteric Fractures of the Hip;J. Bone Jt. Surg. Br.,1997
3. Importance of Locking Plate Positioning in Proximal Humeral Fractures as Predicted by Computer Simulations;J. Orthop Res. Soc.,2019
4. Postoperative Malrotation After Closed Reduction and Intramedullary Nailing of the Femur: A Retrospective 5-Year Analysis;Z. Orthop. Unfallchirurg.,2014
5. Radiation Exposure to an Orthopedic Surgeon;Clin. Orthop. Relat. Res.,1984
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献