Affiliation:
1. Mechanical Engineering, Stanford University, Standford, Calif.
Abstract
Several current designs for high effectiveness gas turbine regenerators involve low Reynolds number fully developed, laminar flow type surfaces. Such surfaces consist of cylindrical flow passages, of small hydraulic radius, in parallel. The cylinder geometry may, as examples, be triangular, as in some glass-ceramic surfaces, or rectangular, as in deepfold metal foil surfaces. This presentation demonstrates that manufacturing tolerances of several thousandths of an in. in passage dimension have a significant influence on the overall heat transfer and flow friction behavior. The analysis is also useful in rationalizing the difference between theory and test results for the basic heat transfer (j factor) and friction (f factor) characteristics as a function of Reynolds number for various surfaces of the laminar flow type.
Cited by
23 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. References;Fundamentals of Heat Exchanger Design;2023-09-21
2. Design of perforated plate for uniform flow distribution in heat-exchanger unit of SFR steam generator;Journal of Mechanical Science and Technology;2021-07-22
3. Thermal Design;Compact Heat Exchangers;2017
4. Nonuniformities in compact heat exchangers—scope for better energy utilization: A review;Renewable and Sustainable Energy Reviews;2014-12
5. Heat Exchanger Thermal Design;Heat Exchanger Design Handbook, Second Edition;2013-05-03