Affiliation:
1. Thermophysical Properties Division, National Engineering Laboratory, National Bureau of Standards, Boulder, Colo. 80303
Abstract
Transient forced convection heat transfer coefficients for both subcritical and supercritical helium in a rectangular flow channel heated on one side were measured during the application of a step in heat flux. Zero flow data were also obtained. The heater surface which served simultaneously as a thermometer was a fast response carbon film. Operating conditions covered the following range: Pressure, 1.0 × 105 Pa (1 bar) to 1.0 × 106 Pa (10 bar); Temperature, 4 K–10 K; Heat Flux, 0.1 W/cm2−10 W/cm2; Reynolds number, 0–8 × 105. The experimental data and a predictive correlation are presented.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. CRYOGENIC MEASUREMENTS;Handbook of Measurement in Science and Engineering;2016-07-01
2. Fluid Cooling;digital Encyclopedia of Applied Physics;2015-12-08
3. Technology, Preparation, and Characterization;Applied Superconductivity;2015-01-30
4. Experimental Investigation of Transient Forced Convection of Liquid Methane in a Channel at High Heat Flux Conditions;Experimental Heat Transfer;2014-10-31
5. A porous medium analogy for the helium flow in CICCs;International Journal of Heat and Mass Transfer;2008-05