Methodology to Characterize Row Manifolds for High Power Direct to Chip Liquid Cooling Data Centers

Author:

Shahi Pardeep1,Heydari Ali1,Eslami Bahareh1,Radmard Vahideh1,Hinge Chandraprakash2,Modi Himanshu23,Chinthaparthy Lochan Sai Reddy2,Tradat Mohammad1,Agonafer Dereje2,Rodriguez Jeremy1

Affiliation:

1. NVIDIA Corporation , 2788 San Tomas Expressway, Santa Clara, CA 95051

2. Department of Mechanical and Aerospace Engineering, The University of Texas at Arlington , Arlington, TX 76019

3. The University of Texas at Arlington

Abstract

Abstract Demand is growing for the dense and high-performing IT computing capacity to support artificial intelligence, deep learning, machine learning, autonomous cars, the Internet of Things, etc. This led to an unprecedented growth in transistor density for high-end CPUs and GPUs, creating thermal design power (TDP) of even more than 700 watts for some of the NVIDIA existing GPUs. Cooling these high TDP chips with air cooling comes with a cost of the higher form factor of servers and noise produced by server fans close to the permissible limit. Direct-to-chip cold plate-based liquid cooling is highly efficient and becoming more reliable as the advancement in technology is taking place. Several components are used in the liquid-cooled data centers for the deployment of cold plate-based direct-to-chip liquid cooling like cooling loops, rack manifolds, CDUs, row manifolds, quick disconnects, flow control valves, etc. Row manifolds used in liquid cooling are used to distribute secondary coolant to the rack manifolds. Characterizing these row manifolds to understand the pressure drops and flow distribution for better data center design and energy efficiency is important. In this paper, the methodology is developed to characterize the row manifolds. Water-based coolant Propylene glycol 25% was used as the coolant for the experiments and experiments were conducted at 21 °C coolant supply temperature. Two, six-port row manifolds' P-Q curves were generated, and the value of supply pressure and the flowrate were measured at each port. The results obtained from the experiments were validated by a technique called flow network modeling (FNM). FNM technique uses the overall flow and thermal characteristics to represent the behavior of individual components.

Publisher

ASME International

Reference24 articles.

1. Choosing Between Room, Row, and Rack-Based Cooling for Data Centers,2012

2. The Different Types of Air Conditioning Equipment for IT Environments,2004

3. Characterization of Parallel and Opposed Control Dampers to Observe the Effect on Thermal Mixing of Air Streams in an Air-Cooling Unit,2022

4. Experimental Failure Analysis of a Rear Door Heat Exchanger With Localized Containment;IEEE Trans. Compon., Packag. Manuf. Technol.,2017

5. An Experimental and Theoretical Investigation of the Extent of Bypass Air Within Data Centres Employing Aisle Containment, and Its Impact on Power Consumption;Appl. Energy,2017