High-Resolution Computational Fluid Dynamic Simulation of Haemodialysis Cannulation in a Patient-Specific Arteriovenous Fistula

Author:

Fulker David1,Ene-Iordache Bogdan2,Barber Tracie1

Affiliation:

1. School of Mechanical and Manufacturing Engineering, University of New South Wales, Ainsworth Building, Kensington Campus, Kensington, NSW 2025, Australia e-mail:

2. Department of Biomedical Engineering, IRCCS—Istituto di Ricerche Farmacologiche “Mario Negri,” Ranica, BG 24020, Italy e-mail:

Abstract

Arteriovenous fistulae (AVF) are the preferred choice of vascular access in hemodialysis patients; however, complications such as stenosis can lead to access failure or recirculation, which reduces dialysis efficiency. This study utilized computational fluid dynamics on a patient-specific radiocephalic fistula under hemodialysis treatment to determine the dynamics of access recirculation and identify the presence of disturbed flow. Metrics of transverse wall shear stress (transWSS) and oscillatory shear index (OSI) were used to characterize the disturbed flow acting on the blood vessel wall, while a power spectral density (PSD) analysis was used to calculate the any turbulence within the access. Results showed that turbulence is generated at the anastomosis and continues through the swing segment. The arterial needle dampens the flow as blood is extracted to the dialyzer, while the venous needle reintroduces turbulence due to the presence of jet flows. Adverse shear stresses are present throughout the vascular access and coincide with these complex flow fields. The position of the needles had no effect in minimizing these forces. However, improved blood extraction may occur when the arterial needle is placed further from the anastomosis, minimizing the effects of residual turbulent structures generated at the anastomosis. Furthermore, the arterial and venous needle may be placed in close proximity to each other without increasing the risk of access recirculation, in a healthy mature fistula, due to the relatively stable blood flow in this region. This may negate the need for a long cannulation segment and aid clinicians in optimizing needle placement for hemodialysis.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3