Affiliation:
1. Research Centre Rez, Hlavní 130, Husinec-Rež 250 68, Czech Republic e-mail:
Abstract
Three-dimensional Monte Carlo code KENO-VI of SCALE-6.2.2 code system was applied for criticality calculation of the LR-0 reactor core. A central module placed in the center of the core was filled by graphite, lithium fluoride-beryllium fluoride (FLIBE), and lithium fluoride-sodium fluoride (FLINA) compounds. The multiplication factor was obtained for all cases using both ENDF/B-VII.0 and ENDF/B-VII.1 nuclear data libraries. Obtained results were compared with benchmark calculations in the MCNP6 using ENDF/B-VII.0 library. The results of KENO-VI calculations are found to be in good agreement with results obtained by the MCNP6. The discrepancies are typically within tens of pcm excluding the case with the FLINA filling. Sensitivities and uncertainties of the reference case with no filling were determined by a continuos-energy version of the TSUNAMI sequence of SCALE-6.2.2. The obtained uncertainty in multiplication factor due to the uncertainties in nuclear data is about 650 pcm with ENDF/B-VII.1.
Funder
European Regional Development Fund
Ministerstvo Školství, Mládeže a Tělovýchovy
Subject
Nuclear Energy and Engineering,Radiation
Cited by
1 articles.
订阅此论文施引文献