Affiliation:
1. Turbopropulsion Laboratory, Department of Aeronautics and Astronautics, Naval Postgraduate School, Monterey, CA 93943
Abstract
A detailed two-component LDV mapping of the flow through a controlled diffusion compressor cascade at low Mach number ( ~ 0.25) and Reynolds number of about 7 × 105, at three inlet air angles from design to near stall, is reported. It was found that the suction-side boundary layer reattached turbulent after a laminar separation bubble, and remained attached to the trailing edge even at the highest incidence, at which losses were 3 to 4 times the minimum value for the geometry. Boundary layer thickness increased to fill 20 percent of the blade passage at the highest incidence. Results for pressure-side boundary layer and near-wake also are summarized. Information sufficient to allow preliminary assessment of viscous codes is tabulated.