Misalignment Error in Cancellous Bone Apparent Elastic Modulus Depends on Bone Volume Fraction and Degree of Anisotropy

Author:

Bennison Matthew B. L.1,Pilkey A. Keith2,Lievers W. Brent1

Affiliation:

1. Bharti School of Engineering, Laurentian University, Sudbury, ON P3E 2C6, Canada

2. Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON K7L 3N6, Canada

Abstract

Abstract Cancellous bone is an anisotropic structure with architectural and mechanical properties that vary due to both skeletal site and disease state. This anisotropy means that, in order to accurately and consistently measure the mechanical properties of cancellous bone, experiments should be performed along the primary mechanical axis (PMA), that is, the orientation in which the mechanical properties are at their maximum value. Unfortunately, some degree of misalignment will always be present, and the magnitude of the resulting error is expected to be architecture dependent. The goal of this work is to quantify the dependence of the misalignment error, expressed in terms of change in apparent elastic modulus (ΔE), on both the bone volume fraction (BV/TV) and the degree of anisotropy (DA). Finite element method (FEM) models of bovine cancellous bone from five different skeletal sites were created at 5 deg and 20 deg from the PMA determined for each region. An additional set of models was created using image dilation/erosion steps in order to control for BV/TV and better isolate the effect of DA. Misalignment error was found to increase with increasing DA and decreasing BV/TV. At 5 deg misaligned from the PMA, error is relatively low (<5%) in all cases but increases to 8–24% error at 20 deg. These results suggest that great care is needed to avoid introducing misalignment error into experimental studies, particularly when studying regions with high anisotropy and/or low bone volume fraction, such as vertebral or osteoporotic bone.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3