A Genetic Algorithm Based Multi-Objective Shape Optimization Scheme for Cementless Femoral Implant

Author:

Chanda Souptick1,Gupta Sanjay2,Kumar Pratihar Dilip1

Affiliation:

1. Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India

2. Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India e-mail:

Abstract

The shape and geometry of femoral implant influence implant-induced periprosthetic bone resorption and implant-bone interface stresses, which are potential causes of aseptic loosening in cementless total hip arthroplasty (THA). Development of a shape optimization scheme is necessary to achieve a trade-off between these two conflicting objectives. The objective of this study was to develop a novel multi-objective custom-based shape optimization scheme for cementless femoral implant by integrating finite element (FE) analysis and a multi-objective genetic algorithm (GA). The FE model of a proximal femur was based on a subject-specific CT-scan dataset. Eighteen parameters describing the nature of four key sections of the implant were identified as design variables. Two objective functions, one based on implant-bone interface failure criterion, and the other based on resorbed proximal bone mass fraction (BMF), were formulated. The results predicted by the two objective functions were found to be contradictory; a reduction in the proximal bone resorption was accompanied by a greater chance of interface failure. The resorbed proximal BMF was found to be between 23% and 27% for the trade-off geometries as compared to ∼39% for a generic implant. Moreover, the overall chances of interface failure have been minimized for the optimal designs, compared to the generic implant. The adaptive bone remodeling was also found to be minimal for the optimally designed implants and, further with remodeling, the chances of interface debonding increased only marginally.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference81 articles.

1. Dual-Energy X-Ray Absorptiometry Measurement of Bone Mineral Density Around Porous-Coated Cementless Femoral Implants;J. Bone Jt. Surg., Br.,1993

2. Mathematical Optimization of Elastic Properties: Application to Cementless Hip Stem Design;ASME J. Biomech. Eng.,1997

3. Prognosis of Total Hip Replacement, a Swedish Multicenter Study of 4664 Revisions;Acta Orthop. Scand.,1990

4. Projections of Primary and Revision Hip and Knee Arthroplasty in the United States From 2005 to 2030;J. Bone Jt. Surg., Am. Vol.,2007

5. The Application of Numerical Shape Optimization to Artificial-Joint Design,1988

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3