Possible Sources of Discrepancy Between Sphygmomanometer Cuff Pressure and Blood Pressure Quantified in a Collapsible-Tube Analogue

Author:

Bertram C. D.1,Butcher K. S. A.1

Affiliation:

1. Centre for Biomedical Engineering, University of New South Wales, Kensington, Sydney, Australia 2033

Abstract

This paper examines the assumption that the audible events detected as Korotkov sounds in sphygmomanometry occur when blood pressure equals arm-cuff pressure. Several effects that contribute to discrepancy between these pressures are quantified using an idealised arm-and-cuff system consisting of a thick-walled collapsible tube subject to external compression along a central part of its length. The effects studied are (1) transverse pressure difference, resulting from tissues sustaining a part of the external compression through (a) circumferential bending stiffness and (b) longitudinal curvature of the tensed localised neck at the site of initial collapse, (2) longitudinal pressure difference between upstream pressure and pressure at the collapse point due to both (a) viscous and (b) inertial pressure drop. These effects are found to compensate partially for each other; the pressure within the vessel at the collapse point is less than the cuff pressure, but is also less than the blood pressure at the upstream end of the cuff. All four of the contributing terms increase proportionally to the flow-rate raised to a power greater than one, except the viscous pressure drop. Owing to a progressive shortening of the collapsed neck as flow-rate increases, the viscous term is almost independent of the flow-rate. The overall discrepancy displays less flow-rate dependency and is smaller than some of the terms which contribute to it. This means that considerable accuracy is needed if measurements of the effects are to be used to correct the raw data on cuff pressure at the time of Korotkov sound emission so as to obtain an improved estimate of the blood pressure.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3