Affiliation:
1. Allied Valve Industries, Inc., Chicago, IL 60622
Abstract
A design method for safety and safety-relief valve test equipment is presented which is applicable to compressible media. A test stand pressure vessel is sized for an assumed ideal valve operation. In this way, a minimum size is determined which will allow the measured safety valve performance to be characteristic of the valve and not the test equipment.
Subject
Mechanical Engineering,Mechanics of Materials,Safety, Risk, Reliability and Quality
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Zone modelling of high-lift pressure relief valves;Building Services Engineering Research and Technology;2000-11
2. Design of High-Lift Pressure Relief Valves with Non-Adjustable Blowdown for Gas/Steam;Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering;1995-02