A New Automated Method for the Quantification of Mitral Regurgitant Volume and Dynamic Regurgitant Orifice Area based on a Normalized Centerline Velocity Distribution using Color M-mode and Continuous Wave Doppler Imaging
Author:
Deserranno Dimitri1, Greenberg Neil L.1, Thomas James D.1, Garcia Mario J.1
Affiliation:
1. Cleveland Clinic Foundation, Department of Cardiology, Cardiovascular Imaging, 9500 Euclid Ave, Desk F15, Cleveland, OH 44195
Abstract
Previous echocardiographic techniques for quantifying valvular regurgitation (PISA) are limited by factors including uncertainties in orifice location and hemispheric convergence assumption. Using computational fluid dynamics simulations, we developed a new model for the estimation of orifice diameter and regurgitant volume without the aforementioned assumptions of the PISA technique. Using experimental data obtained from the in vitro flow model we successfully validated our new model. The model output (y) and reference (x) values were in close agreement (y=0.95x+0.38,r=0.96,error=1.68±7.54% for the orifice diameter and y=1.18x−4.72,r=0.93,error=6.48±16.81% for the regurgitant volume).
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference17 articles.
1. Enriquez-Sarano, M., Tajik, A. J., Schaff, H. V., Orszulak, T. A., Bailey, K. R., and Frye, R. L., 1994, “Echocardiographic Prediction of Survival after Surgical Correction of Organic Mitral Regurgitation,” Circulation, 90, pp. 830–837. 2. Dujardin, K. S., Enriquez-Sarano, M., Bailey, K. R., Nishimura, R. A., Seward, J. B., and Tajik, A. J., 1997, “Grading of Mitral Regurgitation by Quantitative Doppler Echocardiography. Calibration by left Ventricular Angiography in Routine Clinical Practice,” Circulation, 96, pp. 3409–3415. 3. Thomas, J. D., Liu, C. M., Flachskampf, F. A., O’Shea, J. P., Davidoff, R., and Weyman, A. E., 1990, “Quantification of Jet Flow by Momentum Analysis. An In Vitro Color Doppler Flow Study,” Circulation, 81, pp. 247–259. 4. Zhang, J., Shiota, T., Shandas, R., Deng, Y. B., Weintraub, R., Paik, J., Liepmann, D., and Sahn, D. J., 1993, “Effects of Adjacent Surfaces on Different Shapes of Regurgitant Jet Sizes: An In Vitro Study Using Color Doppler Imaging and Laser-illuminated Dye Visualization,” J. Am. Coll. Cardiol., 22, pp. 1522–1528. 5. Maciel, B. C., Moises, V. A., Shandas, R., Simpson, I. A., Beltran, M., Valdes-Cruz, L., and Sahn, D. J., 1991, “Effect of Pressure and Volume of the Receiving Chamber on the Spatial Distribution of Regurgitant Jets as Imaged by Color Doppler Flow Mapping. An In Vitro study,” Circulation, 83, pp. 605–613.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|