Impact of an Earth-Air Heat Exchanger Combined With Nighttime Ventilation on Indoor Thermal Comfort of a Residential Building in Hot Semi-Arid Climate

Author:

Mahach Hassan12,Lafqir Fatima-Ezzahra3,Benhamou Brahim3,Bennouna Amin4,Schmidt Christoph5,Groß Bodo5,Altgeld Horst5

Affiliation:

1. Cadi Ayyad University ProcEDE Laboratory; EnR2E Laboratory, National Center for Studies and Research on Water and Energy (CNEREE), , Marrakech , Morocco ; , Saarbrücken , Germany

2. IZES gGmbH ProcEDE Laboratory; EnR2E Laboratory, National Center for Studies and Research on Water and Energy (CNEREE), , Marrakech , Morocco ; , Saarbrücken , Germany

3. Cadi Ayyad University ProcEDE Laboratory; EnR2E Laboratory, National Center for Studies and Research on Water, and Energy (CNEREE), , Marrakech , Morocco

4. Cadi Ayyad University Laboratory of Nanomaterials for Energy and the Environment (LN2E), Faculty of Sciences Semlalia, , Marraekch , Morocco

5. IZES gGmbH , Saarbrücken , Germany

Abstract

Abstract This work aims at investigating the impact of an Earth-Air Heat eXchanger (EAHX) on the thermal comfort when it is added to a natural nighttime ventilation for a house located in Marrakech (Morocco), which is characterized by a hot semi-arid climate. The thermal behavior of the house associated with this cooling combination was assessed using dynamic simulations. Two transient models are used, the well-validated Type 460 model of trnsys software (Transient System Simulation) for the EAHX and a separate trnsys-based model for the building, recently validated using an onsite long-term monitoring of the house under study in the present work. Many configurations of the house ranging from the building without any passive technique to the building with envelope thermal insulation connected with the EAHX combined with natural nighttime ventilation strategy have been investigated. The results showed that the nighttime ventilation strategy alone keeps the operative temperature lower than the convenient 28 °C for 92% of the time during the cooling period. On the other hand, when the EAHX alone is used, the operative temperature is lower than 28 °C during 57% of the time during the hot season. Hence, it was concluded that the passive nighttime ventilation alone leads already to a great thermal comfort improvement; however, its combination with an additional EAHX system results in convenient temperatures lower than 28 °C for 99% of time during the complete cooling period. It is found also that by applying nighttime ventilation, the air blowing flowrate can be reduced by up to three air change per hour while keeping the same EAHX’ parameters.

Funder

Académie Hassan II des Sciences et Techniques

Centre National pour la Recherche Scientifique et Technique

Publisher

ASME International

Subject

Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3