Affiliation:
1. Department of Mechanical Engineering, University of Hong Kong, Hong Kong
Abstract
A theory is presented for predicting the transient behavior of bubbles in the downcomer and riser loop. It is found that a sudden drop in boiler pressure could seriously reduce the circulation velocity and this is attributed to steam formation in the downcomer tube. The reduction of the circulation velocity tends to prolong existence of individual bubbles in the water phase and therefore increases the water level swell. Transient behavior of circulation velocity in the riser, and water level responses in the steam drum were measured in a two-tube experimental boiler following a step increase in steam control-valve opening for various boiler pressures.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献