Transient Data Processing of Flow Boiling Local Heat Transfer in a Multi-Microchannel Evaporator Under a Heat Flux Disturbance

Author:

Huang Houxue1,Lamaison Nicolas2,Thome John R.3

Affiliation:

1. Laboratory of Heat and Mass Transfer (LTCM), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IGM-LTCM, Station 9, Lausanne CH-1015, Switzerland e-mail:

2. Laboratory of Heat and Mass Transfer (LTCM), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IGM-LTCM, Station 9, Lausanne CH-1015, Switzerland

3. Professor Laboratory of Heat and Mass Transfer (LTCM), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IGM-LTCM, Station 9, Lausanne CH-1015, Switzerland

Abstract

Multi-microchannel evaporators are often used to cool down electronic devices subjected to continuous heat load variations. However, so far, rare studies have addressed the transient flow boiling local heat transfer data occurring in such applications. The present paper introduces and compares two different data reduction methods for transient flow boiling data in a multi-microchannel evaporator. A transient test of heat disturbance from 20 to 30 W cm−2 was conducted in a multi-microchannel evaporator using R236fa as the test fluid. The test section was 1 × 1 cm2 in size and had 67 channels, each having a cross-sectional area of 100 × 100 μm2. The micro-evaporator backside temperature was obtained with a fine-resolution infrared (IR) camera. The first data reduction method (referred to three-dimensional (3D)-TDMA) consists in solving a transient 3D inverse heat conduction problem by using a tridiagonal matrix algorithm (TDMA), a Newton–Raphson iteration, and a local energy balance method. The second method (referred to two-dimensional (2D)-controlled) considers only 2D conduction in the substrate of the micro-evaporator and solves at each time step the well-posed 2D conduction problem using a semi-implicit solver. It is shown that the first method is more accurate, while the second one reduces significantly the computational time but led to an approximated solution. This is mainly due to the 2D assumption used in the second method without considering heat conduction in the widthwise direction of the micro-evaporator.

Publisher

ASME International

Subject

Electrical and Electronic Engineering,Computer Science Applications,Mechanics of Materials,Electronic, Optical and Magnetic Materials

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3