Assessment of Two-Phase Cooling of Power Electronics Using Roll-Bonded Condensers

Author:

Gradinger Thomas B.1,Agostini Francesco1

Affiliation:

1. ABB Switzerland, Ltd., Corporate Research, Segelhofstrasse 1K, Baden-Daettwil 5405, Switzerland e-mail:

Abstract

Two-phase thermosyphons with condensers from roll-bonded panels, short “roll-bond thermosiphons,” are attractive for power-electronics cooling. Using simulations, the performance of roll-bond thermosyphons and classical heat sinks is compared. The roll-bond thermosyphons are advantageous in terms of trade-off between thermal resistance, cooler volume or mass, and sound-power level. Under forced convection, where air-side heat-transfer coefficients are comparatively high, the classical heat sink suffers from low fin efficiency and limited heat spreading. By increasing the number of panels, the roll-bond thermosyphon enables low thermal resistances that cannot be practically reached with classical heat sinks. For free air convection, the roll-bond thermosyphon allows a significant reduction of thermal resistance and cooler mass.

Publisher

ASME International

Subject

Fluid Flow and Transfer Processes,General Engineering,Condensed Matter Physics,General Materials Science