Numerical Evaluations of an Uncemented Acetabular Component in Total Hip Arthroplasty: Effects of Loading and Interface Conditions

Author:

Saviour Ceby Mullakkara1,Banerjee Chowdhury Joydeep2,Gupta Sanjay1

Affiliation:

1. Department of Mechanical Engineering, Indian Institute of Technology Kharagpur , Kharagpur 721 302, West Bengal, India

2. Joint and Bone Care Hospital , DD-35, Sector 1, Salt Lake, Kolkata 700 064, West Bengal, India

Abstract

Abstract Using finite element (FE) models of intact and implanted hemipelvises, the study aimed to investigate the influences of musculoskeletal loading and implant–bone interface conditions on preclinical analysis of an uncemented acetabular component after total hip arthroplasty (THA). A new musculoskeletal loading dataset, corresponding to daily activities of sitting up–down, stairs up–down and normal walking, for a pelvic bone was generated based on previously validated Gait2392 model. Three implant–bone interface conditions, fully bonded and debonded having two rim press-fits (1 mm and 2 mm), were analyzed. High tensile (2000–2415 μϵ) and compressive strains (900–1035 μϵ) were predicted for 2 mm press-fit, which might evoke microdamage in pelvic cortex. Strain shielding in periprosthetic cancellous bone was higher for bonded condition during sitting up activity, compared to other combinations of interface and loading conditions. Only the nodes around acetabular rim (less than 6%) were susceptible to interfacial debonding. Although maximum micromotion increased with increase in press-fit, postoperatively for all load cases, these were within a favorable range (52–143 μm) for bone ingrowth. Micromotions reduced (39–105 μm) with bone remodeling, indicating lesser chances of implant migration. Bone apposition was predominant around acetabular rim, compared to dome, for all interface conditions. Periprosthetic bone resorption of 10–20% and bone apposition of 10–15% were predicted for bonded condition. Whereas for press-fit (1 mm and 2 mm), predominant bone apposition of 200–300% was observed. This study highlights the importance of variations in loading and interface conditions on in silico evaluations of an uncemented acetabular component.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3