Dependence of Anisotropy of Human Lumbar Vertebral Trabecular Bone on Quantitative Computed Tomography-Based Apparent Density

Author:

Aiyangar Ameet K.12,Vivanco Juan34,Au Anthony G.5,Anderson Paul A.6,Smith Everett L.7,Ploeg Heidi-Lynn3

Affiliation:

1. Laboratory for Mechanical Systems Engineering (304), EMPA (Swiss Federal Laboratories for Materials Science and Technology) Dübendorf, Überlandstrasse 129, CH-8600 Dübendorf, Zürich 8600, Switzerland

2. Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI 53706 e-mail:

3. Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI 53706

4. Facultad de Ingeniería y Ciencias, Universidad Adolfo Ibáñez, Viña del Mar, Chile

5. VibeDx Diagnostic Corp., Edmonton, AB T5J4P6, Canada

6. Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705

7. Department of Population Health Sciences, University of Wisconsin-Madison, Madison, WI 53706

Abstract

Most studies investigating human lumbar vertebral trabecular bone (HVTB) mechanical property–density relationships have presented results for the superior–inferior (SI), or “on-axis” direction. Equivalent, directly measured data from mechanical testing in the transverse (TR) direction are sparse and quantitative computed tomography (QCT) density-dependent variations in the anisotropy ratio of HVTB have not been adequately studied. The current study aimed to investigate the dependence of HVTB mechanical anisotropy ratio on QCT density by quantifying the empirical relationships between QCT-based apparent density of HVTB and its apparent compressive mechanical properties— elastic modulus (Eapp), yield strength (σy), and yield strain (εy)—in the SI and TR directions for future clinical QCT-based continuum finite element modeling of HVTB. A total of 51 cylindrical cores (33 axial and 18 transverse) were extracted from four L1 human lumbar cadaveric vertebrae. Intact vertebrae were scanned in a clinical resolution computed tomography (CT) scanner prior to specimen extraction to obtain QCT density, ρCT. Additionally, physically measured apparent density, computed as ash weight over wet, bulk volume, ρapp, showed significant correlation with ρCT [ρCT = 1.0568 × ρapp, r = 0.86]. Specimens were compression tested at room temperature using the Zetos bone loading and bioreactor system. Apparent elastic modulus (Eapp) and yield strength (σy) were linearly related to the ρCT in the axial direction [ESI = 1493.8 × (ρCT), r = 0.77, p < 0.01; σY,SI = 6.9 × (ρCT) − 0.13, r = 0.76, p < 0.01] while a power-law relation provided the best fit in the transverse direction [ETR = 3349.1 × (ρCT)1.94, r = 0.89, p < 0.01; σY,TR = 18.81 × (ρCT)1.83, r = 0.83, p < 0.01]. No significant correlation was found between εy and ρCT in either direction. Eapp and σy in the axial direction were larger compared to the transverse direction by a factor of 3.2 and 2.3, respectively, on average. Furthermore, the degree of anisotropy decreased with increasing density. Comparatively, εy exhibited only a mild, but statistically significant anisotropy: transverse strains were larger than those in the axial direction by 30%, on average. Ability to map apparent mechanical properties in the transverse direction, in addition to the axial direction, from CT-based densitometric measures allows incorporation of transverse properties in finite element models based on clinical CT data, partially offsetting the inability of continuum models to accurately represent trabecular architectural variations.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3