Effects of Elastic Modulus Change in Helical Tubes Under the Influence of Dynamic Changes in Curvature and Torsion

Author:

Selvarasu N. K. C.1,Tafti Danesh K.2

Affiliation:

1. Mechanical Engineering Department, Virginia Polytechnic Institute and State University, 114-I Randolph Hall, Mail Code 0238, Blacksburg, VA 24061

2. Mechanical Engineering Department, Virginia Polytechnic Institute and State University, 114-I Randolph Hall, Mail Code 0238, Blacksburg, VA 24061 e-mail:

Abstract

The incidence of stent late restenosis is high (Zwart et al., 2010, “Coronary Stent Thrombosis in the Current Era: Challenges and Opportunities for Treatment,” Curr. Treat. Options Cardiovasc. Med., 12(1), pp. 46–57) despite the extensive use of stents, and is most prevalent at the proximal and distal ends of the stent. Elastic modulus change in stented coronary arteries subject to the motion of the myocardium is not studied extensively. It is our objective to understand and reveal the mechanism by which changes in elastic modulus and geometry contribute to the generation of nonphysiological wall shear stress (WSS). Such adverse hemodynamic conditions could have an effect on the onset of restenosis. Three-dimensional (3D), spatiotemporally resolved computational fluid dynamics (CFD) simulations of pulsatile flow with moving wall boundaries and fluid structure interaction (FSI) were carried out for a helical artery with physiologically relevant flow parameters. To study the effect of coronary artery (CA) geometry change on stent elastic modulus mismatch, models where the curvature, torsion and both curvature and torsion change were examined. The elastic modulus is increased by a factor of two, five, and ten in the stented section for all three modes of motion. The changes in elastic modulus and arterial geometry cause critical variations in the local pressure and velocity gradients and secondary flow patterns. The pressure gradient change is  47%, with respect to the unstented baseline when the elastic modulus is increased to 10. The corresponding WSS change is 15.4%. We demonstrate that these changes are attributed to the production of vorticity (vorticity flux) caused by the wall movement and elastic modulus discontinuity. The changes in curvature dominate torsion changes in terms of the effects to local hemodynamics. The elastic modulus discontinuities along with the dynamic change in geometry affected the secondary flow patterns and vorticity flux, which in turn affects the WSS.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference60 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3