The tube-to-tubesheet joint strength is measured in terms of residual contact pressure between the tube’s outer surface and tubesheet hole surfaces. The joint integrity is affected by several design parameters, including the type of tube and-tubesheet materials, level of expansion and the initial radial clearance between the tube and tubesheet. In the present work, an axisymmetric finite element model based on the sleeve diameter and rigid roller concepts is developed. The model has been used to evaluate the combined effects of clearance, wall reduction level and the-strain hardening of tube and tubesheet materials on the interfacial pressure between tube and tubesheet. The FE results show that the initial clearance effect is dependent on the strain hardening capability of the tube material. For low strain hardening tube material the interfacial pressure remains almost constant well above the TEMA (Tubular Exchanger Manufacturing Association) maximum radial over tolerance of 0.0254 mm. These results are validated by the experimental data developed during the research program. As expected, a drastic reduction in joint strength is observed at high values of radial clearances. The cut-off clearance (clearance at which the interfacial pressure starts to drop) is found to vary linearly with the level tube material hardening level. The residual pressure is found to increase slightly for moderate strain hardening tube materials but shows lower cut-off clearances. Wall reductions ranging from 1% to 10% were utilized in calculating the contact pressure as a function of radial clearance. The results show that for low strain hardening materials the optimum value of residual contact stress is obtained for the industry recommended value of 5%. Finally, because of the absence plastic deformation in the ligament, the level of tubesheet material strain hardening does not have any noticeable effect to the joint strength.

Publisher

ASMEDC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3