Biaxial Mechanical Properties of the Native and Glutaraldehyde-Treated Aortic Valve Cusp: Part II—A Structural Constitutive Model
Author:
Billiar Kristen L.1, Sacks Michael S.2
Affiliation:
1. Department of Biomedical Engineering, University of Miami, Coral Gables, FL 33124 2. Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261
Abstract
We have formulated the first constitutive model to describe the complete measured planar biaxial stress–strain relationship of the native and glutaraldehyde-treated aortic valve cusp using a structurally guided approach. When applied to native, zero-pressure fixed, and low-pressure fixed cusps, only three parameters were needed to simulate fully the highly anisotropic, and nonlinear in-plane biaxial mechanical behavior. Differences in the behavior of the native and zero- and low-pressure fixed cusps were found to be primarily due to changes in the effective fiber stress–strain behavior. Further, the model was able to account for the effects of small <10deg misalignments in the cuspal specimens with respect to the biaxial test axes that increased the accuracy of the model material parameters. Although based upon a simplified cuspal structure, the model underscored the role of the angular orientation of the fibers that completely accounted for extreme mechanical anisotropy and pronounced axial coupling. Knowledge of the mechanics of the aortic cusp derived from this model may aid in the understanding of fatigue damage in bioprosthetic heart valves and, potentially, lay the groundwork for the design of tissue-engineered scaffolds for replacement heart valves. [S0148-0731(00)00504-5]
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference52 articles.
1. Krucinski, S., Vesely, I., Dokainish, M. A., and Campbell, G., 1993, “Numerical Simulation of Leaflet Flexure in Bioprosthetic Valves Mounted on Rigid and Expansile Stents,” J. Biomech., 26, pp. 929–943. 2. Christie, C. W., and Medland, I. C., 1982, “A Non-linear Finite Element Stress Analysis of Bioprosthetic Heart Valve,” Finite Element in Biomechanics, Gallagher, R. H., Simon, B. R., Johnson, P. C., and Gross, J. F., eds., Chichester, Wiley, pp. 153–179. 3. Lee, J. M., Courtman, D. W., and Boughner, D. R., 1984, “The Glutaraldehyde-Stabilized Porcine Aortic Valve Xenograft. I. Tensile Viscoelastic Properties of the Fresh Leaflet Material,” J. Biomed. Mater. Res., 18, pp. 61–77. 4. Lee, J. M., Boughner, D. R., and Courtman, D. W., 1984, “The Glutaraldehyde-Stabilized Porcine Aortic Valve Xenograft. II. Effect of Fixation With or Without Pressure on the Tensile Viscoelastic Properties of the Leaflet Material,” J. Biomed. Mater. Res., 18, pp. 79–98. 5. Vesely, I., and Noseworthy, R., 1992, “Micromechanics of the Fibrosa and the Ventricularis in Aortic Valve Leaflets,” J. Biomech., 25, pp. 101–113.
Cited by
311 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|