Simulation of Fretting Wear at Orthopaedic Implant Interfaces

Author:

Ebramzadeh Edward1,Billi Fabrizio1,Sangiorgio Sophia N.1,Mattes Sarah1,Schmoelz Werner1,Dorr Lawrence1

Affiliation:

1. Biomechanics Laboratory of the J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Los Angeles Orthopaedic Hospital∕UCLA and The Dorr Arthritis Institute of Centinela Hospital, Inglewood, California

Abstract

Osteolysis due to wear debris is a primary cause of failure of total joint replacements. Although debris produced by the joint articulating surfaces has been studied and simulated extensively, fretting wear debris, produced at nonarticulating surfaces, has not received adequate attention. We developed a three-station fretting wear simulator to reproduce in vivo motion and stresses at the interfaces of total joint replacements. The simulator is based on the beam bending theory and is capable of producing cyclic displacement from 3to1000microns, under varying magnitudes of contact stresses. The simulator offers three potential advantages over previous studies: The ability to control the displacement by load, the ability to produce very small displacements, and dynamic normal loads as opposed to static. A pilot study was designed to test the functionality of the simulator, and verify that calculated displacements and loads produced the predicted differences between two commonly used porous ingrowth titanium alloy surfaces fretting against cortical bone. After 1.5 million cycles, the simulator functioned as designed, producing greater wear of bone against the rougher plasma-sprayed surface compared to the fiber-mesh surface, as predicted. A novel pin-on-disk apparatus for simulating fretting wear at orthopaedic implant interfaces due to micromotion is introduced. The test parameters measured with the fretting wear simulator were as predicted by design calculations, and were sufficient to measure differences in the height and weight of cortical bone pins rubbing against two porous ingrowth surfaces, plasma-sprayed titanium and titanium fiber mesh.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference38 articles.

1. Modularity of Prosthetic Implants;Barrack;J. Am. Acad. Orthop. Surg.

2. Concerns with Modularity in Total Hip Arthroplasty;Bobyn;Clin. Orthop.

3. Boggan, R. S., Lemons, J. E., and Rigney, E. D., 1994, “Clinical and Laboratory Investigations of Fretting and Corrosion of a Three-Component Modular Femoral Stem Design,” J. Long Term Eff. Med. Implants, 4, pp. 177–191.

4. Fretting Corrosion Accelerates Crevice Corrosion of Modular Hip Tapers;Brown;J. Appl. Biomater

5. Mechanisms of Failure of Modular Prostheses;Collier;Clin. Orthop.