Affiliation:
1. School of Energy and Power Engineering, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100191, China
Abstract
Abstract
A set of foam metal casing treatment (FMCT) has been investigated to assess the stability improvement and noise reduction on an axial compressor. Three FMCTs with different PPI (Pores Per Inch), 20, 35, and 50, are tested experimentally. Two installation locations of foam metal in the casing are also considered and investigated. At location 1, it is found that the FMCT improves the stall margin by 5.4–8.7%, and the attenuation of compressor noise is up to 5 dB. At location 2, the stall margin is extended by 22.2–37.1% but increasing the noise mostly. Besides, foam metal at location 1 causes less efficiency loss than that at location 2. Based on the analysis in near-casing pressure distribution, spanwise performance comparison, and stall process, the mechanism of the FMCT for enhancing the compressor stability is also discussed.
Funder
National Natural Science Foundation of China
Reference25 articles.
1. Compression System Stability and Active Control;Paduano;Annu. Rev. Fluid Mech.,2001
2. Spike-Type Compressor Stall Inception, Detection, and Control;Tan;Annu. Rev. Fluid Mech.,2010
3. Experimental Evaluation of Outer Case Blowing or Bleeding of Single Stage Axial Flow Compressor, Part VI Final Report;Koch,1970
4. Passive Endwall Treatments for Enhancing Stability;Hathaway,2007
5. Stall Margin Improvement by Casing Treatment—Its Mechanism and Effectiveness;Takata;ASME J. Eng. Power,1977
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献