Performance Characterization of the Effect of Axial Positioning of Bend Skewed Casing Treatment Retrofitted to a Transonic Axial Flow Compressor

Author:

Alone Dilipkumar B.1,Kumar Subramani Satish1,Thimmaiah Shobhavathy1,Mudipalli Janaki Rami Reddy1,Pradeep A. M.2,Ramamurthy Srinivasan1,Iyengar Venkat S.1

Affiliation:

1. CSIR-NAL, Bangalore, India

2. Indian Institute of Technology Bombay, Powai, India

Abstract

The performance of an aero-engines to a large extend depends on the performance behavior of axial flow compressors and is restricted by the compressor instabilities like rotating stall and surge. In the present study, attempts have been made to design and develop the bend skewed casing treatment geometries with lower porosities to improve the stable operating range of single stage axial flow compressor. Experimental investigations were undertaken to study the impact of axial position of one of the casing treatment geometry on the single stage transonic axial flow compressor. The transonic compressor used for the current experimental studies has a stage total to total pressure ratio of 1.35, corrected mass flow rate of 22 kg/s at an operating speed of 12930 rpm. The compressor stage steady and unsteady state response for 20%, 40%, 60% and 100% axial chord coverage relative to the rotor tip chord of the bend skewed casing treatment with a porosity of 33% was studied experimentally. The objective was to identify the optimum axial location; which will give maximum improvement in the stall margin with minimal loss of compressor stage efficiency. Through an experimental study it was observed that the axial location of bend skewed casing treatment plays a very crucial role in governing the performance of the transonic compressor. For all the investigated axial coverages, compressor stall margin increases but the optimum performance in terms of stall margin improvement and efficiency gains were observed at 20% and 40% of the rotor chord. This trend shows good agreement with existing published literature. An improvement of 31.7% in the stall margin with an increase in the stage efficiency was obtained at one of the axial coverage. Maximum improvement of 37% in the stall margin above the solid casing was noticed at 60% axial coverage. The stalling characteristics of the compressor stage also changes with the axial positions. In the presence of solid casing the nature of stall was abrupt and stalls cells travels at half the rotor speed. The blade element performance also studied at the rotor exit using pre-calibrated aerodynamic probe.

Publisher

American Society of Mechanical Engineers

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Numerical Analysis of a Novel Casing Treatment in an Axial Flow Fan;Journal of Propulsion and Power;2024-07-01

2. Impact of the ending position of controllable speed casing on the flow stability in a transonic compressor rotor;Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy;2023-02-07

3. Casing Treatment: Its Potential and Limitations;Journal of Turbomachinery;2022-11-07

4. Effect of axial slot casing treatment on a counter-rotating axial-flow compressor aerodynamic performance and stability;Proceedings of the Institution of Mechanical Engineers, Part G: Journal of Aerospace Engineering;2022-08-12

5. Understanding of an Effect of Plenum Volume of a Low Porosity Bend Skewed Casing Treatment on the Performance of Single-Stage Transonic Axial Flow Compressor;Proceedings of the National Aerospace Propulsion Conference;2020-08-01