A Preliminary Biomechanical Assessment of a Polymer Composite Hip Implant Using an Infrared Thermography Technique Validated by Strain Gage Measurements

Author:

Bougherara Habiba,Rahim Ehsan1,Shah Suraj2,Dubov Anton3,Schemitsch Emil H.4,Zdero Rad5

Affiliation:

1. Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, M5B-2K3, Canada

2. Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, M5B-2K3, Canada; Martin Orthopaedic Biomechanics Lab, St. Michael’s Hospital, Toronto, ON, M5B-1W8, Canada

3. Martin Orthopaedic Biomechanics Lab, St. Michael’s Hospital, Toronto, ON, M5B-1W8, Canada

4. Martin Orthopaedic Biomechanics Lab, St. Michael’s Hospital, Toronto, ON, M5B-1W8, Canada; Department of Surgery, Faculty of Medicine, University of Toronto, Toronto, ON, M5S-1A8, Canada

5. Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, M5B-2K3, Canada; Martin Orthopaedic Biomechanics Lab, St. Michael’s Hospital, Toronto, ON, M5B-1W8, Canada e-mail:

Abstract

With the resurgence of composite materials in orthopaedic applications, a rigorous assessment of stress is needed to predict any failure of bone-implant systems. For current biomechanics research, strain gage measurements are employed to experimentally validate finite element models, which then characterize stress in the bone and implant. Our preliminary study experimentally validates a relatively new nondestructive testing technique for orthopaedic implants. Lock-in infrared (IR) thermography validated with strain gage measurements was used to investigate the stress and strain patterns in a novel composite hip implant made of carbon fiber reinforced polyamide 12 (CF/PA12). The hip implant was instrumented with strain gages and mechanically tested using average axial cyclic forces of 840 N, 1500 N, and 2100 N with the implant at an adduction angle of 15 deg to simulate the single-legged stance phase of walking gait. Three-dimensional surface stress maps were also obtained using an IR thermography camera. Results showed almost perfect agreement of IR thermography versus strain gage data with a Pearson correlation of R2 = 0.96 and a slope = 1.01 for the line of best fit. IR thermography detected hip implant peak stresses on the inferior-medial side just distal to the neck region of 31.14 MPa (at 840 N), 72.16 MPa (at 1500 N), and 119.86 MPa (at 2100 N). There was strong correlation between IR thermography-measured stresses and force application level at key locations on the implant along the medial (R2 = 0.99) and lateral (R2 = 0.83 to 0.99) surface, as well as at the peak stress point (R2 = 0.81 to 0.97). This is the first study to experimentally validate and demonstrate the use of lock-in IR thermography to obtain three-dimensional stress fields of an orthopaedic device manufactured from a composite material.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献