Affiliation:
1. Department of Mechanical Engineering, Kyushu Institute of Technology, Tobata, Kitakyushu, Japan
Abstract
A new combined five-hole probe with hemispherical head of 2.0 mm diameter is developed for the measurement of nonsteady three-dimensional water flow. Each pressure hole is connected to a small semiconductor pressure transducer, which has a high frequency response, and the instantaneous pressure can be measured continuously by the probe. In the case of nonsteady flow, pressures detected by the probe are affected by the inertia due to flow unsteadiness. Therefore, in order to achieve an accurate nonsteady flow measurement, it is vital to reduce the inertial effects from the pressure reading. In the present study the inviscid flow analysis was carried out to evaluate the error due to the inertial effect, and the iterative correction procedure was examined by computer simulation.
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献