Fibrin Glue and Conduit Form a Composite Structure in Digital Nerve Repair

Author:

Schimoler Patrick J.1,Pope David2,Kharlamov Alexander2,Tang Peter2,Miller Mark Carl1

Affiliation:

1. Orthopaedic Surgery Department, Allegheny General Hospital, Allegheny Health Network, Pittsburgh, PA 15212; University of Pittsburgh, Pittsburgh, PA 15261

2. Orthopaedic Surgery Department, Allegheny General Hospital, Allegheny Health Network, Pittsburgh, PA 15212

Abstract

Abstract Repair of severed nerves without autograft or allograft has included suture, suture with glue alone, suture with conduit and suture with glue augmentation to conduit, where use of conduit is considered for separation of the nerve ends from 5 mm to 3 cm. Repairs must not only serve acutely to provide apposition of nerve ends but must enable the healing of the nerve. Using biological conduit can place suture at the ends of the conduit while fibrin glue alone eliminates suture but with limited strength. The combination of conduit and glue offers the growth guidance of conduit with sufficient strength from the glue to maintain the nerve within the conduit. The role of fibrin glue in the integrity of the repair remains an open question, however. We sought to determine the factors in the strength of a glue-conduit-nerve construct and include consideration of standard suture repair. Fresh-frozen cadaveric digital nerves were repaired with suture alone, with glue alone or with suture and glue together and then loaded to failure. Previously tested specimens with conduit, suture and glue were considered for comparison. The suture alone (2.02 N) and suture with glue (2.24 N) were not statistically different from each other but were statistically stronger than glue alone (0.15 N). When compared to the earlier results of the strength of conduit with glue (0.65 N), these simple results show that the glue and conduit act together. The increased area over which the glue adheres to the nerve and conduit creates a composite structure stronger than either alone.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3